Product Name
- Malti-Parameter Patient Monitor
Model
- GMT-104
Description:
Features &Benefits:

. 6standard parameters: ECG,RESP,NIBP,SPO2,1-TEMP,PR/HR.

. 12.1" high resolution color TFT LTD display..

. Real time S-T segment analysis,pace-maker detection and ARR

analysis.

. Drug calculation and titration table.

. Multidisplay selectable including standard,large font,trend

coexis,OxyCRG dynamic view and bed-to-bed view display.

. Indication of Incorrect manipulation and malfunction analysis.

On-line help and Patient info input management

. Multi-lead ECG waveforms display in phase.

Large volume of tabular and graphic trends information storage

and easy to recall.

. Capture dynamic waveforms.

. Efficient resistance to interference of defibrillator and HF knife.

. Up to 4 hours working capacity of built-in rechargeable battery.

. Networking capacity and TCP/IP networking platform.

. Option of IBP and EtCO2

Specifications

Performance Specifications

Display: 12.1" color TFT

Rolling and refreshing waveform display

Resolution:800??00

Multi display selectable including:

Large-font display

Trend coexist display

OxyCRG dynamic view display.

Bed-to-bed view display

Trace: 9 waveforms(7 ECG, 1 SPO2 and 1 RESP)

Sweep speed: 12.5mm/s,25mm/s,50mm/s

Indicator: Power/battery indicator light

QRS beep and alarm sound

Battery: Rechargeable lead acid cell,12v/4AH

Max.24 hour for charging,4 hours for continue

working

Trend time: Above 72 hours

Alarm: User-adjustable High,Medium and Low limits 3-

level Audible and visual alarm

Networking: Connected to central monitoring system

Tcp/Ip netting platform

Recorder: Build-in ,thermal array

Plethysmogram caveform:2 channels

Record mode: manual, on alarm, time-defined

Recording width:50mm

Printing speed:50mm/s

Recording type: Frozen waveform record

NIBP recall record

Trend table record

Alarm record

Fixed -time record

ECG

Lead mode: 5 - lead(R,L,F,N,C)

Lead selection : I,II,III,avR,avL,avF,V

Waveform: 2 and 7 channel selectable

Gain selection:

0.25mm/mv,0.5mm/mv,1mm/mv,2mm/mv

Sweep speed: 12.5mm/s;25mm/s;50mm/s

Heart rate range:

Adult: 15~300bpm;Neonate:/pediatric:15~350bpm

Accuracy: +1bpm or +1%,whichecer is greater

Resolution: 1bpm

Filter: surgery mode:1~20Hz

monitor model:0.5~40Hz

Diagnostic mode:0.05~130Hz

Scaling signal: 1mv +3%

Protection: withstand 4000VAC/50 voltage isolation

against electrosurgical interference and

defibrillation

Alarm range: 15~350bpm

S-T segment detecton:

Measurement range: 2.0mV~+2.0mV

Alarm Range: 2.0mV~ +2.0mV

Accuracy: -0.8mV ~+0.8Mv

Error: +0.02Mv

Arrhythmia analysis: YES

NIBP

Method: Digital Automatic oscillometric

Operation mode : Manual/Automatic/continuous

Auto measurement time: Adjustable(1~480min)

Measurement Unit: mmHg/Kpa selectable

Measurement types: Systolic,Diastolic,Mean

Measurement tange:

Range of Systolic pressure: Adult:40~270mmHg

Pediatric:40~220mmHg

Neonate:40~135mmHg

Range of mean pressure: Adult:20~235mmHg

Pediatric:20~165mmHg

Neonate:20~110mmHg

Range of diastolic pressure: Adult:10~215mmHg

Pediatric:10~150mmHg

Neonate:10~100mmHg

Over-pressure protection: Double safety protection

Resolution: 1 mmHg

Alarm: Systolic.Diastolic,Mean

SPO2

Measurement range: 0~100%

Resolution: 1%

Accuracy: +2%(70-100%);0-69% unspecified

Alarm range 0~100%

Pluse Rate: range:20~300bpm

Resolution:1bpm

Error:+1bpm or +2%,whichever is greater

RESPIRATION

Method: Thoracic impedance

Measurement range: Adult:7~120rpm;

Neonate/Pediatric:7~150rpm

Apnea alarm: YES,10~40s

Resolution: 1rpm

Accuracy: +2rpm

TEMPERATURE

Compatible probe: YSI or CYF

Measurement range: 5~50 Centigrade

Resolution : 0.1 Centigrade

Accuracy: +0.1 Centigrade

Refreshing time: about 1

Average measuring time: <10s

EtCO2

Sidertream CO2

Measurement range: 0~99mmHg

Accuracy: +2mmHg(0~40mmHg)

Sampling Range: 100ml/min

Sampling rate accuracy: 15%

Respiration rate 0~120rmp

Respiration accuracy: +2rmp(0~70rmp) +-5rmp(>70rmp)

Respiration time: <240msec(10% to 90%)

Delay time: <2s

Standard Configuration: ECG, NIBP,RESP,1-TEMP,SPO2,PR

Optional: Thermal Recorder,1-IBP,2-IBP,ETCO2

Miscellaneous

Satety:

Safety level: Class I, type CFDimendion and Weight

Dimendion: 440 x 430 x 450

G.Weight: <9.0KS

Operation Environment

Temperature: Working 0~+40 Centigrade

Transportation and storage - 20~+60 Centigrade

Humidity: working < = 85%

Transportation and storage < = 93%

Power: AC 100-240,50/60Hz

Patient range: Neonate,pediatric,and adult patients

Accessories supplies

(1) 5 lead ECG cable

(2) 1 spo2 probes

(3) 1 NIBP prbe

(4) 1 temp probe

(5)1 ground connecting liner

(6) Chest electrode (10pcs/set)

Contact Detail

Address: Rm 702, Block 20, Wei Mian Village Xia Meilin, Futian District Shenzhen, China 518031 CN
Tel: 86-755-83104601
Fax: 86-755-83104601
E-mail:
Other Website: www.greatmed.com.cn